计划生产YJV22  阻燃电力电缆ZR-VV
6kV~35kV 中低压铜芯及铝芯交联聚乙烯绝缘电力电缆(YJV电缆,YJV22电缆,YJLV电缆,YJLV22电缆)XLPE Insulated Power Cable   | 
交联聚乙烯绝缘电力电缆是采用化学方法或物理方法,使聚乙烯分子由线型分子结构转变为三维网状结构,由热塑性的聚乙烯变成热固性的交联聚乙烯,从而提高了聚乙烯的耐老化性能、机械性能和耐环境能力,并保持了优良的电气性能。    交联聚乙烯绝缘电力电缆导体的允许长期zui高温为90摄氏度,较低绝缘电缆、聚氯乙烯绝缘电缆和聚乙烯绝缘电缆高,且具有重量轻、结构简单、使用方便、耐化学腐蚀和敷设不受落差限制等优点。 26/35KV电力电缆,18/30KV交联电缆,12/20KVYJV电缆,8.7/15KVYJV22电缆线,6/10KV铝芯交联电缆线,3.6/6KVYJLV单芯电缆    中低压交联电缆产品标准  Standard         本产品按GB12706《额定电压35V及以下铜芯、铝芯塑料绝缘电力电缆》标准生产,同时还可根据用户需要按电工委员会推荐标准IEC、英国标准、德国标准及美国标准生产。 The product is manufactured according to the standard of《GB12706 or IEC、BS、DIN and ICEA upon request. 适用范围  Applications   本产品适用于工频额定电压3.6/6kv~26/35kv输配电线路作配送电能子用。 The product is suitable for use in power transmission and distribution lines with rated power frequency voltage 3.6/6kv~26/35kv. 使用特性  Operating characteristics · 工频额定电压U0/U为3.6/6kv~26/35kv。 Rated power-frepuency voltage U0/U: 3.6/6kv~26/35kv. · 电缆导体的zui高允许工作温度:90℃。    Max.admissible operating temperature of the conductor:90℃. · 短路时(zui长时间不超过5s)电缆导体的zui高温度不超过2500C。 Max. short-circurt temperature of conductor shall not exceed 2500C. (5s maximum duration) · 电缆敷设时环境温度应不低于00C。 The ambient temperature under installation should not below 00C. · 电缆弯曲半径:三芯电缆不小于电缆外径15倍;单芯电缆不小于电缆外径20倍。 The bending radius of a single-core cable should not less than 20 times of the cable diameter.  The bending radius of a single-core cable should not less than 15 times of the cable diameter.  电缆额定电压的选择   Voltage designation · 电缆的额定电压应适合于电缆系统的运行状况,用U0/U(Um)kv表示。 U0-电缆设计用的导体对地或金属屏蔽之间的额定工频电压; U-电缆设计用的导体间的额定工频电压; Um-设备可承受的“zui高系统电压"的zui大值。 The rated voltage of the cable for a given applixation shall be suitable for the operating conditions in the system in which the cable is used,and is expressed in the form of U0/U(Um)kv Where: U0-The rated power-frequency voltage between conductors and earth metallic screen ,for which the cable designed; U - The rated power-frequency voltage between conductos, for which the cable designed; Um- The maximum value of the“highest system voltage"for which the equipment may beused. · 三相系统用电缆的U0值推荐如下表: The values of U0 recommened for cable to be used in three-phase systems are listed below:   | 
U kv  | U m kv  | U 0 * kv  |  A 和 B 类系统 System categories A and B  | C 类系统 Systems categories C  | 
  |  6  | 7.2  | 3.6  | 6  | 
  |  10  | 12  | 6  | 8.7  | 
  |  15  | 17.5  | 8.7  | 12  | 
  |  20  | 24  | 12  | 18  | 
  |  30  | 36  | 18  | -  | 
  |  35  | 40.5  | 21  | 26  | 
  |  
 
 
  | 
A类系统──该类系统任何一相导体与地和接地导体接触时,能在1min内与系统分离 B类系统──该类系统仅包括单相接地故障短时运行的条件,接地故障时间应不超过1h, 但在任何情况下,zui长不超过8h每年接地故障总持续时间不超过125h; C类系统──不属于A类、B类的系统。 System category A──This category comprises those systems in which any phase conductor that comes in contact with earth or an earth conductor. is disconnected from the system within 1 min. System category B ──This category comprises those system which,under faultconditions,are operated,are operated for ashorttimewith one phase earthed.This period should not exceed 1 h..Fora longer period, not exceeding 8h on any occasion, can be tolerated.The total duration of earth faults in any year should not exceed 125h. System categeory C──This category comprises all systems which do not fall into A and B 电缆的型号Type of cable        | 
型号 Type  | 名称 Designation  | 适用范围 Application  |  YJV  | 铜芯交联聚乙烯绝缘氯乙烯护套电力电缆 Copper conductor,XLPE insulated and PVC sheathed power cable  | 室内、隧道及电缆沟等场所,不能承受机械外力。单芯电缆不允许敷设在磁性管道中。 For laying indoors 、 intunnel or cable trench,unable to bear external mechan-icalforces.Single-core cable in magnetic duct is not permissible  |  YJLY  | 铝芯交联聚乙烯绝缘乙烯护套电力电缆 Aluminium conductor, XLPE insulated and PVC sheathed power cable  |  YJY  | 铜芯交联聚乙烯绝缘氯乙烯护套电力电缆 Copper conductor ,XLPE insulated and PEsheathed power cable  |  YJLY  | 铝芯交联聚乙烯绝缘氯乙烯护套电力电缆 Alumimium conductor ,XLPE  |  
    | 
产品介绍:高压交联电缆产品具有传输容量大,工作温度,不受落差的限制,安装敷设方便等特点,广泛应用于工矿企业和城市电网中。高压交联电缆主要用于电力、建筑、工矿、冶金、交通等部门的动力、照明输配电系统,由于聚乙烯是电绝缘性能的塑料,加上经过高分子交联后成为热固性材料,因此其电性能好,机械性能和耐热性好。近二十年来,已成为中国中、高压电缆的主导品种,产品适用于6——35KV的各个电压级中它可分为:YJV-交联聚乙稀绝缘聚氯乙烯护套电力电缆,YJV22-交联聚乙烯绝缘钢带铠装高压电缆,YJLV-交联聚乙烯绝缘铝芯钢带铠装高压电缆。
执行标准:GB/T12706-2002
使用特性     
· 工频额定电压U0/U为6kv/10kv~26/35kv。
· 电缆导体的zui高允许工作温度:90℃。
· 短路时(zui长时间不超过5s)电缆导体的zui高温度不超过2500C。
· 电缆敷设时环境温度应不低于00C。
· 电缆弯曲半径:三芯电缆不小于电缆外径15倍;单芯电缆不小于电缆外径20倍。
电缆额定电压的选择
· 电缆的额定电压应适合于电缆系统的运行状况,用U0/U(Um)kv表示。
U0-电缆设计用的导体对地或金属屏蔽之间的额定工频电压;
U-电缆设计用的导体间的额定工频电压;
Um-设备可承受的“zui高系统电压"的zui大值。
产品参数:
  
导体标称截面  | 绝缘 厚度  | 护套 厚度  | 电缆近似外径  | 电缆近似重量  | 20℃ 导体  | 电缆载流量  | 短路电流  | 
直流 电阻  | 在空 气中  | 直埋土壤中  | 导 体  | 屏蔽层  | 
铜带  | 铜丝  | 
mm 2  | mm  | mm  | mm  | kg/km  | Ω/km  | A  | A  | KA  | KA  | KA  | 
3×25  | 3.4  | 2.4  | 48  | 3190  | 0.727  | 120  | 125  | 3.69  | 2.958  | -  | 
3×35  | 3.4  | 2.5  | 50  | 3731  | 0.524  | 140  | 155  | 5.15  | 2.958  | -  | 
3×50  | 3.4  | 2.6  | 53  | 4396  | 0.387  | 165  | 180  | 7.31  | 2.958  | -  | 
3×70  | 3.4  | 2.7  | 57  | 5198  | 0.268  | 210  | 220  | 10.2  | 2.958  | -  | 
3×95  | 3.4  | 2.9  | 62  | 6350  | 0.193  | 355  | 265  | 13.8  | 2.958  | -  | 
3×120  | 3.4  | 3  | 65  | 7257  | 0.153  | 290  | 300  | 17.4  | 2.958  | -  | 
3×150  | 3.4  | 3.1  | 69  | 8383  | 0.124  | 330  | 340  | 21.7  | 2.958  | -  | 
3×185  | 3.4  | 3.2  | 72  | 9741  | 0.0991  | 375  | 380  | 26.7  | 2.958  | -  | 
3×240  | 3.4  | 3.3  | 78  | 11854  | 0.0754  | 435  | 435  | 34.6  | 3.301  | -  | 
3×300  | 3.4  | 3.4  | 84  | 14861  | 0.0601  | 495  | 485  | 43.1  | 3.301  | -  | 
计划生产YJV22  阻燃电力电缆ZR-VV